Main body :High-strength engineering plastic rack, light,
Main body :High-strength engineering plastic rack, light,
Anesthesia Machine
Main body :High-strength engineering plastic rack, light,
beautiful and corrosion resistant
Scope of application :adult, child
Gas source :O2: 0.27~0.55MPa N2O: 0.27~0.55MPa
Flow meter :
O2: 0.1~1.0L/min 1.1~10L/min
N20: 0.1~1.0L/min 1.1~10L/min
O2, N2O linkage and N2O Stopper
When using nitrous oxide, oxygen concentration>25%;
When the oxygen pressure<0.2Kpa, the flow of nitrous oxide would be cut off.
Flow rate of rapid oxygen supply 25~75L/min
Low oxygen pressure alarm :There will be sound alarm when the oxygen pressure < 0.2MPa
Vaporizer
it has the function of automatic compensation based on pressure, temperature, and flow rate.
The regulation range of evaporator concentration is 0~5 vol%.
Among Halothane,Enflurane,Isoflurane and Sevoflurane,two can be chosen for application as required by the customer. And vaporizers that are imported with original packaging are also available.
Respiratory circuit : working mode: all-close, semi-close, semi-open. APL: 0.5~7 kPa
Respiratory Bellows:bellows for adults, bellows for children
tidal volume range:0~1,500 ml
Ventilator
Display mode:High-definition 5.7” LCD screen display
Ventilation mode :IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH
Ventilation parameters
Tidal volume:50~1500 ml
Rate:2~99 bpm
SIMV rate: 2~20 bpm
I:E : 2:1~1:8
Inspiratory trigger pressure -1.0~2.0 kPa
PEEP :0~2.0 kPa
Pressure range :1.0~6.0 kPa
SIGH :1.5 times the inspiratory time
Parameters for ventilation monitoring tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure
Monitoring of oxygen concentration (21%~100%)
Security Alarm System
Oxygen Concentration alarm
upper limit setting range (50%~100%)
low limit setting range (15%~50%)
Airway pressure alarm
upper limit setting range 1.0~6.0 kPa
low limit setting range 0.4~2.0 kPa
Per-minute ventilation volume alarm
upper limit setting range 3.0~30L/min
low limit setting range 1.0~10L/min
Sustained high-pressure alarm:it will give alarm when stress have consistently been higher than 2.5 kPa
Suffocation alarm: it will give sound and light alarm if there is no tidal volume input for 15 seconds
Power alarm
Power :AC 220V±10% 50Hz±1Hz(Optional UPS, Storage battery)
(Mechanical Arms)(End-expiratory CO2 monitoring)
*Items within brackets are optional.
Q:What's the minimum order quantity (MOQ)?
A:For most of our medical products, even order for only one unit is warmly welcomed.
Q: Can you do OEM/ private label?
A: Of course we can do OEM/private label for you.
Q: What's your delivery time?
A: Generally it is 10 days if the goods are in stock.
or it is 15-20 days if the goods are not in stock, it is according to quantity.
Q: How to ship the order?
A: Please inform us your instruction, by sea, by air or by express, any way is ok for us. We have very professional forwarder to provide the best shipping cost, service and guarantee.
Q: What is your terms of payment ?
A: We accept T/T ,LC,Western Union ,Paypal and more.Please suggest your preferred payment method.