Products
LTSP13 8InchesPatient Monitor
  • LTSP13 8InchesPatient Monitor

  • No: LTSP13
  • Type:
  • Dimension:
  • Characteristics:

    Waterproof design, resistance to dropping (1 meter) 


Details

 8" color TFT LCD screen, resolution 800*600

Waterproof design, resistance to dropping (1 meter)

Low power consumption, fanless structure which

     creates no noise

Support external 13-20V DC power, continuously working

     for 5.5 hours above on battery backup, full charge with 2.5

     hours, suitable for Ambulance, Emergency Transport

Display mode: Big font, trends review, 7 leads ECG waveform

      on same screen, and etc

15 kinds of arrhythmia analysis, 15 kinds of drug concentration

      analysis

Anti-electrosurgical unit (300W), anti-defibrillation (360J),

      suitable for Operating Room, General Ward

Digital SpO2 technology, excellent anti- interference

      performance, low perfusion (0.1%)

 

ECG

Lead: Standard 3/5 lead

Lead Mode: 5 Leads (RA, LA, LL, RL,V)

Lead Selection: I, II, III, avR, avL, avF, V

Lead Mode: 3 Leads (RA, LA, LL)

Lead Selection: I, II, III,

Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV

HR and Alarm Range:

        Adult: 15 ~ 300 bpm

        Ped/Neo: 15 ~ 350 bpm

Accuracy: ±1% or±1bpm, which is greater

Resolution: 1 bpm

Sensitivity: > 200 (uVp-p)

Differential Input Impedance: > 5 MΩ

Bandwidth:

        Surgery    1 ~ 20 Hz

        Monitor     0.5 ~ 40 Hz

        Diagnostic  0.05 ~ 130 Hz

CMRR:

        Monitor > 100 dB

        Operation > 100 dB

        Diagnosis > 90 dB

Electrode Offset Potential: ±300mV

Range: ±2 mV ~ ±700 mV

Width: 0.1 ms ~ 2 ms

Rise time: 10 us ~ 100 us

ST Segment Monitoring Range:

        Measurement Range: -2.0 ~ +2.0 mV

        Measurement Accuracy: -0.8 ~ +0.8 mV

        Measurement Error: ±0.02 mV or ±10%

 

RESP

Method: Impedance Between RA-LL or RA-LA

Measuring Impedance Range: 0.3~3 Ω

Base line Impedance Range: 200~4 KΩ

Bandwidth: 0.1~2.5Hz

Resp. Rate:

        Measuring and Alarm Range:

            Adult: 2 ~ 120 BrPM

            Neo/Ped: 2 ~ 150 BrPM

            Resolution: 1 BrPM

            Accuracy: ±2 BrPM

            Apnea Alarm: 10 ~ 40

 

NIBP

Method: Oscillometric

Mode: Manual, Auto, STAT                        

Measuring Interval in Auto Mode:

        1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)

Measuring Period in STAT Mode: 5 Min

Pulse Rate Range: 40 ~ 240 bpm

Measuring and Alarm Range:

        Adult Mode

            SYS 40 ~ 270 mmHg

            DIA 10 ~ 215 mmHg

            MEAN 20 ~ 235 mmHg                       

        Pediatric Mode

            SYS 40 ~ 200 mmHg

            DIA 10 ~ 150 mmHg

            MEAN 20 ~ 165 mmHg

        Neonatal Mode

            SYS 40 ~ 135 mmHg

            DIA 10 ~ 100 mmHg

            MEAN 20 ~ 110 mmHg

Static Pressure Range: 0 ~ 300 mmHg

Static Pressure Accuracy: ±3mmHg

Accuracy: Maximum Average Error ±5mmHg

                  Maximum Standard Deviation ±8mmHg

Overpressure Protection:

        Adult Mode: 300 mmHg

        Pediatric Mode: 240 mmHg

        Neonatal Mode: 150 mmHg

 

 

SpO2

Measuring Range: 0 ~ 100 %

Resolution: 1 %

Accuracy: 70% ~ 100%  ±2 %

                  0% ~ 69% unspecified

Pulse Rate:

        Measuring Range: 20~300 bpm

        Resolution: 1bpm

        Accuracy: ±3bpm

 

 

 

TEMP

Applicable Temperature Sensor: YSI, CYF

Channel: 1

Measuring Range: 0 ~ 50 ℃

Resolution: ±0.1 ℃

Accuracy: ±0.1 ℃ (Do not including sensor error)

 

Dimension: 210*80*175mm (L*W*H)

 

Weight: 1.35kg

 

Standard: 3/5-Lead ECG, RESP, SpO2, NIBP, PR, 1-TEMP

Optional: Mainstream/Sidestream EtCO2, Touch screen


Pictures

Service

Packing & Delivery
UPS/DHL/FEDEX/TNT
We ship goods by UPS/DHL/FEDEX/TNT express takes 3~ 5 days to arrive.
By Sea
The volume of goods is large and needs to go by sea.It takes about one month to arrive.

Aircraft
Aircraft transportation takes 2-7 days to arrive.


Q&A

FAQ

Q:What's the minimum order quantity (MOQ)?
A:For most of our medical products, even order for only one unit is warmly welcomed.

Q: Can you do OEM/ private label?
A: Of course we can do OEM/private label for you.


Q: What's your delivery time?
A: Generally it is 10 days if the goods are in stock.
or it is 15-20 days if the goods are not in stock, it is according to quantity.

Q: How to ship the order?
A: Please inform us your instruction, by sea, by air or by express, any way is ok for us. We have very professional forwarder to provide the best shipping cost, service and guarantee.

Q: What is your terms of payment ?
A: We accept T/T ,LC,Western Union ,Paypal and more.Please suggest your preferred payment method.