LTX09 High Frequency Digital Mobile C-arm System (3.5KW, 63mA)
Packing Detail: 2440*1100*1420mm, 3.9CBM ; NW: 350KG, GW:535KG.
ⅠSpecifications
1. Fluoroscopic Capacity
Max rated capacity : Tube Current 4mA, Tube Voltage 110kV
Automatic Fluoroscopy: Tube Voltage:40kV~110kV Adjust Automatically
Tube Current : 0.3mA~4mA set manually
Manual Fluoroscopy : Continuous Tube Voltage:40kV~110kV
Continuous Tube Current : 0.3mA~4mA
Pulse Fluoroscopy : Continuous Tube Voltage 40kV~110kV Continuous Tube Current 4.1mA~8mA
2. Photography Capacity
Max rated capacity: 3.5 KW
Tube Voltage and Current Combination : 40kV~49kV 1 ~125 mAs
50kV~59kV 1 ~110 mAs
60kV~69kV 1 ~90 mAs
70kV~79kV 1 ~80 mAs
80kV~89kV 1 ~71 mAs
90kV~99kV 1 ~63 mAs
100kV~110kV 1 ~40 mAs
Plateholder Size: 200mm×250mm(8″×10″) or 250mm×300mm(10″×12″)
3.X-ray Tube
X-ray Tube Special for High Frequency
Fixed anode Dual-focus : large focus: 1.5, small focus: 0.6
Inverter Frequency: 40KHz
Thermal capacity: 35KJ (47KHU)
4. VideoSystem
Image Intensifier : Image Intensifier made by TOSHIBA 9″
CCD Vidicon : Ultra low-light CCD camera imported from Japan
Monitor : Horizontal 1000 lines and vertical 800 lines, Bandwidth : 12.5MHz, Image/sec : 75
CCU(central control): Recursive Filter: K=8, 8 images storage, image upright, image overturn,positive & negative image
LIH(last Image Hold), and OSD(monitor display)
5. Structure :
Directive wheel : ±90°revolution,can freely change the moving direction of the unit.
Ascending & Descending Range of Pillar : ≥400mm
C-arm : Forward and Backward Movement: 200mm
Revolution around Horizontal Axis: ±180°
Revolution around Vertical Axis: ±15° , easier to take special positions radiography )
Slip on orbit: 120°(+90°~ -30°)
ⅡFeatures
1、With a compact appearance, and easy to operate;
2、Clinical Video system with high performance,8 images storage
volume, and two 14〞high-resolution monitors;
3、Automatically track fluoroscopy to make the image brightness and
clearness optimum;
4、Automatically store the last image of fluoroscopy to advantage
diagnosis;
5、With a high-quality knockdown X-ray generator to reduce radiation
6、Digital Workstation.
ⅢClause/ Specification
Section A | Main Digital Radiography System |
1.0 | X-ray Generator Each set of X-ray generator unit for general Fluoroscopy and Radiography with at least the following features: |
1.1 | 3-phase ,high frequency converter / inverter, multi-pulse and microprocessor control |
1.2 | Nominal power output 3.5 KW |
1.3 | Tube Voltage :40KV~110KV, Tube current output of 20~63mA ,1.0 mAs~125mAs |
1.4 | Exposure time range :from 2 ms or shorter to 2 seconds or longer |
1.5 | Suitable to operation of dual-focus X-ray tube : Large Focus :1.5mm,Small Focus :0.6 mm |
1.6 | Automatic line voltage compensation |
1.7 | Automatic exposure control with manual override |
1.8 | Digital display of operator pre-set exposure data |
1.9 | Digital display of actual exposure data after X-ray exposure |
1.10 | Self-diagnostic functions with digital display of error codes |
1.11 | Tube-overload indication and protection on the control panel |
1.12 | User programmed radiographic exposure techniques with the following features: |
1.13 | Unique double foot brake controller design makes it convenient to control the instrument inside and outside the operation room. This design can also protect the health care professionals by reducing the opportunity to come into contact with the radiation. |
1.14 | Each exposure programme includes at least 2 additional selections for appropriate patient size compensation ( normal figure, fat figure,thin figure, adult, child , normal position ,lateral position ) |
1.15 | The exposure programmes are user programmable |
1.16 | Selection of exposure programmes are by touch-controls |
1.17 | Alphanumeric display of selected anatomical exposure programme |
1.18 | Integrated radiation exposure switch on generator control console |
1.19 | All necessary protective circuits are incorporated . |
2.0 | X-ray Tube Each set of rotation anode X-ray tube to be mounted to the Tube Carries System with at least the following features: |
Q:What's the minimum order quantity (MOQ)?
A:For most of our medical products, even order for only one unit is warmly welcomed.
Q: Can you do OEM/ private label?
A: Of course we can do OEM/private label for you.
Q: What's your delivery time?
A: Generally it is 10 days if the goods are in stock.
or it is 15-20 days if the goods are not in stock, it is according to quantity.
Q: How to ship the order?
A: Please inform us your instruction, by sea, by air or by express, any way is ok for us. We have very professional forwarder to provide the best shipping cost, service and guarantee.
Q: What is your terms of payment ?
A: We accept T/T ,LC,Western Union ,Paypal and more.Please suggest your preferred payment method.