LTX09 High Frequency Digital Mobile C-arm System
  • LTX09 High Frequency Digital Mobile C-arm System

  • No: LTX09
  • Type:
  • Dimension:
  • Characteristics:

Details

LTX09 High Frequency Digital Mobile C-arm System (3.5KW, 63mA) 

Packing Detail: 2440*1100*1420mm,  3.9CBM ;  NW: 350KG,  GW:535KG.


ⅠSpecifications 

1. Fluoroscopic Capacity  

Max rated capacity :    Tube Current 4mA, Tube Voltage 110kV  

Automatic Fluoroscopy:     Tube Voltage:40kV110kV Adjust Automatically

Tube Current  :      0.3mA4mA set manually  
Manual Fluoroscopy :     Continuous Tube Voltage:40kV110kV
Continuous Tube Current :           0.3mA4mA 
Pulse Fluoroscopy :      Continuous Tube Voltage 40kV110kV  Continuous Tube Current 4.1mA8mA  
2. Photography Capacity 
 Max rated capacity:     3.5 KW 
 Tube Voltage and Current Combination  :   40kV49kV   1 125 mAs
                                                          50kV59kV   1 110 mAs
                                                          60kV69kV   1 90  mAs
                                                          70kV79kV   1 80  mAs
                                                          80kV89kV   1 71  mAs
                                                          90kV99kV   1 63  mAs
                                                          100kV110kV 1 40  mAs 
 Plateholder Size:     200mm×250mm(8″×10″)  or  250mm×300mm10″×12″ 
3.X-ray Tube 
X-ray Tube Special for High Frequency

Fixed anode   Dual-focus :  large focus:  1.5, small focus:  0.6

Inverter Frequency:   40KHz

Thermal capacity:    35KJ (47KHU) 
4. VideoSystem 
 Image Intensifier  :     Image Intensifier made by TOSHIBA 9″

CCD Vidicon  :     Ultra low-light CCD camera imported from Japan                              
 Monitor  :     Horizontal 1000 lines and vertical 800 lines, Bandwidth : 12.5MHz,     Image/sec : 75

CCU(central control):   Recursive Filter: K=8, 8 images storage,  image upright, image overturn,positive & negative image

LIH(last Image Hold), and OSDmonitor display 
5. Structure :
 Directive wheel :     ±90°revolutioncan freely change the moving  direction of the unit.
 Ascending & Descending Range of Pillar  :     ≥400mm 
 C-arm  :      Forward and Backward Movement: 200mm
 Revolution around Horizontal Axis:      ±180°
Revolution around Vertical Axis:       ±15° , easier  to take special positions radiography )
Slip on orbit:    120°(+90° -30°)  

ⅡFeatures 

1、With a compact appearance, and easy to operate;
2Clinical Video system with high performance8 images storage
       volume, and two 14high-resolution monitors;
3Automatically track fluoroscopy to make the image brightness and 
      clearness optimum;
4Automatically store the last image of fluoroscopy to advantage
      diagnosis;
5With a high-quality knockdown X-ray generator to reduce radiation

6Digital Workstation.

ⅢClause/ Specification


Section A

Main Digital Radiography System

1.0

X-ray Generator

Each set of X-ray generator unit for general Fluoroscopy and Radiography with at least the following features:

1.1

3-phase ,high frequency converter / inverter, multi-pulse and microprocessor control

1.2

Nominal power output 3.5 KW

1.3

Tube Voltage :40KV~110KV, Tube current output of 20~63mA ,1.0 mAs~125mAs

1.4

Exposure time range :from 2 ms or shorter to 2 seconds or longer

1.5

Suitable to operation of dual-focus X-ray tube : Large Focus :1.5mm,Small Focus :0.6 mm

1.6

Automatic line voltage compensation

1.7

Automatic exposure control with manual override

1.8

Digital display of operator pre-set exposure data

1.9

Digital display of actual exposure data after X-ray exposure

1.10

Self-diagnostic functions with digital display of error codes

1.11

Tube-overload indication and protection on the control panel

1.12

User programmed radiographic exposure techniques with the following features:

1.13

Unique double foot brake controller design makes it convenient to control the instrument inside and outside the operation room. This design can also protect the health care professionals by reducing the opportunity to come into contact with the radiation.

1.14

Each exposure programme includes at least 2 additional selections for appropriate patient size compensation ( normal figure, fat figure,thin figure, adult, child , normal position ,lateral position )

1.15

The exposure programmes are user programmable

1.16

Selection of exposure programmes are by touch-controls

1.17

Alphanumeric display of selected anatomical exposure programme

1.18

Integrated radiation exposure switch on generator control console

1.19

All necessary protective circuits are incorporated .

2.0

X-ray Tube

Each set of rotation anode X-ray tube to be mounted to the Tube Carries System with at least the following features:

Pictures

Service

Packing & Delivery
UPS/DHL/FEDEX/TNT
We ship goods by UPS/DHL/FEDEX/TNT express takes 3~ 5 days to arrive.
By Sea
The volume of goods is large and needs to go by sea.It takes about one month to arrive.

Aircraft
Aircraft transportation takes 2-7 days to arrive.



Q&A

FAQ

Q:What's the minimum order quantity (MOQ)?
A:For most of our medical products, even order for only one unit is warmly welcomed.

Q: Can you do OEM/ private label?
A: Of course we can do OEM/private label for you.


Q: What's your delivery time?
A: Generally it is 10 days if the goods are in stock.
or it is 15-20 days if the goods are not in stock, it is according to quantity.

Q: How to ship the order?
A: Please inform us your instruction, by sea, by air or by express, any way is ok for us. We have very professional forwarder to provide the best shipping cost, service and guarantee.

Q: What is your terms of payment ?
A: We accept T/T ,LC,Western Union ,Paypal and more.Please suggest your preferred payment method.