16 slice spiral CT
Technical specification
1, technical specifications and parameters
1.1 rack system
1.1.1 frame size: 1900px, angle: ±30 degrees, can be remote control operation into / out, rise / fall bed and scan rack tilt.
1.1.2 slip ring type: low pressure type slip ring
1.1.3 detector type: GOS solid detector
1.1.4 detector array: 32
2.1 X-ray system
2.1.1 bulb tube anode heat capacity: 5.3MHU
2.1.2 The maximum cooling rate of bulb tube is 815 kHU/min
2.1.3 small focus: 0.5 x 1 mm
2.1.4 big focus: 1 x 1 mm
2.1.5 focus to the scanning field and other central distance: 570mm
2.1.6 minimum ball tube voltage: 80kV
2.1.7 maximum ball tube voltage: 140kV
2.1.8 high voltage generator power: 50.4kW
2.1.9 minimum current: 10mA
2.1.10 maximum current: 442mA
2.2 scan bed
2.2.1 maximum scan range (no metal range): 1950mm
2.2.2The highest point in the vertical movement of the bed is 990mm, the lowest of the vertical movement of the bed is: 425mm
2.2.3 maximum bed surface movement speed:150 mm/s; minimum movement speed:5 mm/s
2.2.4 bed surface movement accuracy: ±0.25 mm
2.2.5 the bed load: 250kg
2.3 console and computer system
2.3.1 The main console
2.3.1.1 master computer:HP Z840
2.3.1.2 computer memory: 32GB
2.3.1.3 host hard drive: 7TB
2.3.1.4 CD-ROM disc recorder system (DICOM compatibility)
2.3.1.5 color LCD flat-panel monitors flicker 1 unit (progressive):
2.3.1.6 standard DICOM3.0 interface: standard configuration, with the following functions:
Send / receive
Query / retrieval
Basic print function
Storage
Network interface (RIS / HIS)
2.3.1.7 laser camera interface
2.3.1.8 Remote diagnosis system and remote diagnosis platform
2.3.1.9 virtual photo typesetting function
2.3.1.10 console color 3D display
2.3.2 advanced video postprocessing workstation
2.3.2.1 offers a range of clinical image processing software, such as MPR, VR, SSD, the maximum and minimum software packageProjection; standard configuration volume measurement software.
2.4 scan parameters
2.4.1 scan time: 0.5, 0.6, 0.7, 0.8, 1, 2 sec
2.4.2 imaging speed (number of scan per scan): 16slice/loop
2.4.3 scan layer thickness: 16 x 0.625
2.4.4 scan layer thickness: 0.625mm, 1mm, 1.25mm, 2.5mm, 2mm, 3mm, 4mm, 6mm, 5mm,7mm, 8mm, 9mm, 10mm
2.4.5 minimum reconstruction display field (FOV): 50mm
2.4.6 maximum reconstruction display field (FOV): 12500px
2.4.7 image reconstruction matrix: 512 * 512
2.4.8 single scan time: 100 sec
2.4.9 maximum scan pitch (Factor Pitch): 1.75:1
2.4.10 minimum Factor (Pitch): 0.15:1
2.4.11 positioning piece length: 1890 mm
2.5 image quality
2.5.1 spatial resolution (X, Y axis plane):20 lp/cm 0% MTF
2.5.2 spatial resolution (Z axis):20 lp/cm 0% MTF
2.5.3 density resolution: (indicating the scan conditions): @0.30% 3mm
2.5.4CTDIvol:Head 16.6mGy/100mAs Body; 8.6mGy/100mAs
Q:What's the minimum order quantity (MOQ)?
A:For most of our medical products, even order for only one unit is warmly welcomed.
Q: Can you do OEM/ private label?
A: Of course we can do OEM/private label for you.
Q: What's your delivery time?
A: Generally it is 10 days if the goods are in stock.
or it is 15-20 days if the goods are not in stock, it is according to quantity.
Q: How to ship the order?
A: Please inform us your instruction, by sea, by air or by express, any way is ok for us. We have very professional forwarder to provide the best shipping cost, service and guarantee.
Q: What is your terms of payment ?
A: We accept T/T ,LC,Western Union ,Paypal and more.Please suggest your preferred payment method.