The supply Automatic alarm KVO function when alarm silence
Adjustable residual stress level is adjustable Alarm sound
The supply Automatic alarm KVO function when alarm silence
Adjustable residual stress level is adjustable Alarm sound
Technology parameters of LTSI07 Syringe pump
1, the syringe specification One-time use of 10 ml, 20 ml, 30 ml and 50 ml syringe.
2, choice of velocity of 0.1 ~ 199.9 ml/h (10 ml) 0.1 ~ 299.9 ml/h (20 ml) 0.1 ~ 399.9 ml/h (30 ml) 0.1 ~ 599.9 ml/h (50 ml) setting accuracy of 0.1 ml/h.\"
3, velocity accuracy + / - 2%
4, blocking 40 ~ 70 kPa pressure
5, rapid infusion of 200 ml/h (10 ml syringe), 300 ml/h (20 ml syringe) 400 ml/h (30 ml syringe), 500 ml/h (50 ml syringe)
6, infusion set total 0.1 ~ 50 ml, setting accuracy of 0.1 ml.
7, infusion volume range 1-9999 ml
8, KVO infusion velocity of 0.1 ml/h speed
9, exhaust bubble 200 ml/h (10 ml), 300 ml/h (20 ml) 400 ml/h (30 ml), 500 ml/h (50 ml)
10, BOLUS speed bubble volume 1-9 ml, 200 ml/h (10 ml syringe), 300 ml/h (20 ml syringe), 400 ml/h (30 ml syringe), 600 ml/h (50 ml syringe)
11, noise at 25 ml/h speed acuities were 36 db noise when running
12, alarm boot self-checking, obstruction, nearing completion, completion, undervoltage, standby, mobile battery.
13, type, class I type CF
14 IP, IP grade x 4 splash water equipment
15, display high-resolution remote digital tube display
16, appearance size 24 x 12 x 10.2 CM
17, power less than 10, va
In the 18th and weighs about 1.4 KG
Two working conditions
1 power AC/dc to AC, 100 v - 240 - v, 50/60 hz
Voltage DC12VC, four hours fully charged for pump with 25 ml/h work 4 hours
Environmental conditions temperature 5 ℃ - 2 + 40 ℃
Relative humidity 20% 90% RH or less
3 the atmospheric pressure 860 hpa - 1060 hpa
4 storage conditions temperature + 55 ℃ to 40 ℃, relative humidity 95% RH or less
Three functions automatically detect syringe type transfusion volume display velocity
The supply Automatic alarm KVO function when alarm silence
Adjustable residual stress level is adjustable Alarm sound
Alarm volume can be adjusted The remaining amount of time display
Q:What's the minimum order quantity (MOQ)?
A:For most of our medical products, even order for only one unit is warmly welcomed.
Q: Can you do OEM/ private label?
A: Of course we can do OEM/private label for you.
Q: What's your delivery time?
A: Generally it is 10 days if the goods are in stock.
or it is 15-20 days if the goods are not in stock, it is according to quantity.
Q: How to ship the order?
A: Please inform us your instruction, by sea, by air or by express, any way is ok for us. We have very professional forwarder to provide the best shipping cost, service and guarantee.
Q: What is your terms of payment ?
A: We accept T/T ,LC,Western Union ,Paypal and more.Please suggest your preferred payment method.