Products
LTP900N Multi-parameter Patient Monitor
  • LTP900N Multi-parameter Patient Monitor

  • No: LTP900N
  • Type:
  • Dimension:
  • Characteristics:

    Optional: Touch Screen, Thermal Recorder, 5-lead ECG, 2-IBP,TEMP Sensor,SpO2, ETCO2,Trolley Stand,wall amount


Details

LTP900N Bedside Patient Monitor  


Features &Benefits:

1. 12.1” color TFT display, high resolution: 800×600dpi;

2. Separated para board: ECG, NIBP, SpO2 board;

3. Enables intuitive operation by clicking one the specific parameters or the waveform in real time, standard configuration includes the navigation knob.

4. Real time S-T segment analysis, and ARR analysis;

5. SpO2 Pitch Tone Variation and Drug Dose Calculation;

6. Parameter waveform and characters color selectable

7. Multi-display: Standard, Large font, Trend Coexis, OxyCRG dynamic

8. Standby mode for Energy saving and suspend monitoring;

9. 7-lead ECG waveforms display in phase;

10. Capture dynamic waveforms;

11. Built-in rechargeable lithium battery, and battery volume checking,

12. AC power checking

13. Efficient resistance to interference of defibrillator and HF knife;

14. SpO2 technology accuracy;

15. Networking capacity and TCP/IP networking platform enable abundant future upgrade

16. Time delay switch-off function keep the monitor data restart monitor;

17. Complete and flexible mounting solution for transportation and in-patient monitoring

Standard parameters: 5-lead ECG, SpO2,NIBP, TEMP,RESP,PR,HR.

Optional: Touch Screen, Thermal Recorder, 5-lead ECG, 2-IBP,TEMP Sensor,SpO2, ETCO2,Trolley Stand,wall amount

 

Performance Specifications

Display:        12.1”color TFT

Rolling and refreshing waveform display

Resolution: 800×600

Multi display selectable including:

Large-font display

Trend coexist display

OxyCRG dynamic view display.

Bed-to-bed view display

Trace:             9 waveforms(7 ECG, 1 SPO2 and 1 RESP)

Sweep speed:12.5mm/s,25mm/s,50mm/s

Indicator:          Power/battery indicator light

QRS beep and alarm sound

Battery:           Rechargeable lead acid cell, 12v/4AH

Max.24 hour for charging, 4 hours for continue working

Trend:             Parameter graphic and tabular trends:

5s/piece,8 hours;

1min/piece,168 hours(24hour×7days)

5min/piece,1000 hours.

 

Storage:           NIBP: 1000 groups

Alarm: 200 groups

Full disclosure waveforms: 3600S

SD card external storage

Alarm:     User-adjustable High, Medium and Low limits 3-level

 Audible and visual alarm

Networking:     Connected to central monitoring system

TCP/IP netting platform

Recorder:         Build-in, thermal array

                                Plethysmogram caveform:2 channels

Record mode: manual, on alarm, time-defined

Recording width: 50mm

Printing speed: 50mm/s

Recording type:    Frozen waveform record

NIBP recall record

Trend table record

Alarm record

Fixed -time record

Standard parameter:

ECG:

 Lead mode:    5 –lead(R,L,F,N,C)

Lead selection :   I,II,III,avR,avL,avF,V

Waveform:      3 and 7 channel selectable

Gain selection:   0.5mm/mv,1mm/mv,2mm/mv

Sweep speed:   6.25mm/s;12.5mm/s;25mm/s;50mm/s

Heart rate range:     Adult: 15~300bpm;

Neonate/pediatric:    15~350bpm

Accuracy:    +1bpm or +1%,whichecer is greater

Resolution:    1bpm

Filter:   surgery mode:1~20Hz

monitor model:   0.5~40Hz

Diagnostic mode:   0.05~130Hz

Scaling signal: 1mv,+3%

Protection:   withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation

Alarm range:   15~350bpm

S-T segment detecton:  

Measurement range:  2.0mV~+2.0mV                         

 Alarm Range:    -2.0mV~ +2.0mV

Accuracy:    -0.8mV ~+0.8Mv

Error:     +0.02Mv

 Arrhythmia analysis: YES


SPO2

Measurement range:  0~100%

Resolution:     1%

Accuracy:     +2%(70-100%);0-69% unspecified

Alarm range:      0~100%

Pluse Rate:                

range:   20~300bpm

Resolution:   1bpm

Error:    +1bpm or +2%,whichever is greater

 

NIBP

Method:    Digital Automatic oscillometric

Operation mode :      Manual/Automatic/continuous

Auto measurement time:     Adjustable(1~480min)

Measurement Unit:     mmHg/Kpa selectable

Measurement types:    Systolic, Diastolic, Mean  

Measurement tange:

Range of Systolic pressure:    Adult: 40~270mmHg

Pediatric: 40~220mmHg

Neonate: 40~135mmHg

Range of mean pressure:      Adult: 20~235mmHg

Pediatric: 20~165mmHg

Neonate: 20~110mmHg

Range of diastolic pressure:   Adult: 10~215mmHg

Pediatric: 10~150mmHg

Neonate :10~100mmHg

Over-pressure protection:     Double safety protection

Resolution:     1 mmHg

Alarm:     Systolic.Diastolic,Mean

 

 

RESPIRATION

Method:   Thoracic impedance

Measurement range:     Adult:7~120rpm;Neonate/Pediatric:7~150rpm

Apnea alarm:    YES,10~40s

Resolution:      1rpm

Accuracy:       +2rpm

 

 

TEMPERATURE

Compatible probe:             YSI or CYF

Measurement range:           5~50

Resolution :                   0.1

Accuracy:                    +0.1

Refreshing time:               about 1

Average measuring time:        <10s

 

Optional Parameter:

 

2-IBP

Channel: 2 channels

Range: 50-300mmHg

Resolution: 1mmHg

Accuracy: ±4mmHg(±4%)

Unit: mmHg, Kpa

Converter Sensitivity: 5mV/V/mmHg

Transducer sites: ART/PA/CVP/LAP/RAP/ICP

 

EtCO2( Sidertream CO2)

Measurement range:   0~99mmHg

Accuracy:   +2mmHg (0~40mmHg)

Sampling Range:   100ml/min

Sampling rate accuracy:   15%

Respiration rate:   0~120rmp

Respiration accuracy:  +2rmp (0~70rmp)

+5rmp (>70rmp)

Respiration time:   <240msec (10% to 90%)

Delay time:  <2s

 

EtCO2 (mainstreaam CO2)

Method:   Infrared Spectrum

Range:   0.0-10% (0~76%)

Resolution:   1mmHg (0.1%)

Accuracy:   5%(±4.0 mmHg)

         Or10%(of Readings)

 

Recorder:     

Build-in, thermal array

Plethysmogram caveform:2 channels

Record mode: manual, on alarm, time-defined

Recording width: 50mm

Printing speed: 50mm/s

Recording type:  Frozen waveform record

NIBP recall record

Trend table record

Alarm record

Fixed -time record

 

Dimendion and Weight

Dimendion:      28*42*1200px         

G.Weight:        <6.5KS

 

Operation Environment

Temperature:    Working 0~+40

Transportation and storage –20~+60

Humidity:       working≤85%

Transportation and storage≤93%

Power:          AC 100-240,50/60Hz

Patient range:    Neonate,pediatric,and adult patients

 

 

Accessories supplies

(1) 5 lead ECG cable  

(2) 1 spo2 probes  

(3) 1 NIBP prbe  

(4) 1 temp probe

(5)1 ground connecting liner  

(6) Chest electrode (10pcs/set)


Company Profile
Guangzhou Leyte Medical Equipment Co., Limited
We have been medical field for more than 10 years 
 Speak fluent English, Received professional knowledge training
Pre-Sales Service 
The professional team provides after-sales service online 24 hours a day. 
We offer OEM services.

After-Sales Service
 One year warranty. 
More than 10 years of professional engineers help you solve problems

Factory

 Quality Workplace

 Good Labor relations

 testing equipment

 Competitive Price 

 Reliable Performance 

 High Quality 

Our Customer
Our customers come from all over the world.
Our main market is in Africa.
There is the exhibition.Main exhibition is at Africa. Been to Kenya, South Africa, Nigeria, Dubai and Vietnam.
Packing & Delivery
UPS/DHL/FEDEX/TNT
We ship goods by UPS/DHL/FEDEX/TNT express takes 3~ 5 days to arrive.
By Sea
The volume of goods is large and needs to go by sea.It takes about one month to arrive.

Aircraft
Aircraft transportation takes 2-7 days to arrive.

FAQ

Q:What's the minimum order quantity (MOQ)?
A:For most of our medical products, even order for only one unit is warmly welcomed.

Q: Can you do OEM/ private label?
A: Of course we can do OEM/private label for you.


Q: What's your delivery time?
A: Generally it is 10 days if the goods are in stock.
or it is 15-20 days if the goods are not in stock, it is according to quantity.

Q: How to ship the order?
A: Please inform us your instruction, by sea, by air or by express, any way is ok for us. We have very professional forwarder to provide the best shipping cost, service and guarantee.

Q: What is your terms of payment ?
A: We accept T/T ,LC,Western Union ,Paypal and more.Please suggest your preferred payment method.




Pictures

Service


FAQ

Q:What's the minimum order quantity (MOQ)?
A:For most of our medical products, even order for only one unit is warmly welcomed.

Q: Can you do OEM/ private label?
A: Of course we can do OEM/private label for you.


Q: What's your delivery time?
A: Generally it is 10 days if the goods are in stock.
or it is 15-20 days if the goods are not in stock, it is according to quantity.

Q: How to ship the order?
A: Please inform us your instruction, by sea, by air or by express, any way is ok for us. We have very professional forwarder to provide the best shipping cost, service and guarantee.

Q: What is your terms of payment ?
A: We accept T/T ,LC,Western Union ,Paypal and more.Please suggest your preferred payment method.



Q&A


FAQ

Q:What's the minimum order quantity (MOQ)?
A:For most of our medical products, even order for only one unit is warmly welcomed.

Q: Can you do OEM/ private label?
A: Of course we can do OEM/private label for you.


Q: What's your delivery time?
A: Generally it is 10 days if the goods are in stock.
or it is 15-20 days if the goods are not in stock, it is according to quantity.

Q: How to ship the order?
A: Please inform us your instruction, by sea, by air or by express, any way is ok for us. We have very professional forwarder to provide the best shipping cost, service and guarantee.

Q: What is your terms of payment ?
A: We accept T/T ,LC,Western Union ,Paypal and more.Please suggest your preferred payment method.