LTCR01A Medical portable ESR Analyzer
LTCR01A Medical portable ESR Analyzer
  • LTCR01A Medical portable ESR Analyzer

  • No: LTCR01A
  • Type:
  • Dimension: size:505*445*365mm 12KG
  • Characteristics:

Details

Specifications :

 Number of test samples : 10 items at the same time
Max test speed : 20 samples/hour  
Suited ESR tube: 1.6ml ESR tube(vacuum or normal) 
 Samples volume : 1.6 ml anticoagulant blood(blood 1.28ml+anticoagulant0.32ml), the height of the inputting tube 60 mm   
Accuracy range of sample: 50mm~64mm  
Read resolution : ±0.2mm(westergren method result±1mm) 
Interval of reading :1 minute
Test time :The test time is 30 minutes, equivalents to 1 hour  
westergren method: The test time is 60 minutes, equivalents to 2   hour westergren method 

Display:128×240 LCD screen

Power: 12V(SELV) by external power supply  

 

Packing Details: 505*445*365mm, 0.09CBM;  NW: 9KG, GW:12 KG 

 . Working principle and structure characteristic

The equipment uses the infrared obstacle detection method, scan the tested blood regularly, and automatically detect the sub-interface of red cells and plasma from time to time. The tested data will be converted into results of Wechsler by computer processing. This can be displayed on the LCD screen or printer and can also be transmitted through the serial interface to a computer.

The instrument makes up detection of the host (include infrared detection devices, computer control systems, thermal printer) and the adaptive power supply (SELV) .

The instrument has the large display apparatus; the interface is simple appearance and has the film keyboard operation. The operation is simple and convenient. The instrument has highly automatic functions which can work at any time and continuously detect. 

 The main performance indicators and the work of environmental requirements

1 Normal working conditions 

aRelative humidity≤70%

bAway from strong sources of electromagnetic interference 

cPrevent dust and vibration, air mustn’t contain corrosive gases, pollution level 2 

dPower220×(1±10 %)V50×(1 ±2 %)Hz

eInput power40×1+10%VA

fEnvironment with good grounding, transient over-voltage category of Class  

g5-minute warm-up time boot. 

2 Environmental conditions of storage and transportation

(a)Ambient temperature range  -20+55

(1) Relative humidity range  ≤93%

(2) Atmospheric pressure range   500hpa1060hpa

(3) No corrosive gas, a well-ventilated. 

3 Basic parameters 

a) Test a sample bit: Instrument detection of up to 10 samples at the same time; 

b) The maximum detection rate: 20 samples / h

c) Blood sedimentation tube: After the State Drug Administration of the registered register vacuum,blood sedimentation tube φ8.3 * 120 vacuum tubes ( ordinary blood sedimentation tube) 

d) Sample size  blood drawing 1.60ml+ anticoagulant agent 0.4ml

e)The permissible error of adding the samples range50mm  64mm

f)Instrument readings resolution  ±0.1mm results of  Wechsler±1mm);

g)Reading time interval 1 minute

h) Testing Time: 30 minutes, which is equivalent to 1 hour Wechsler; the testing time of equipment is 60 minutes, which is equivalent to two hours Wechsler;

i) Display: 128x240 dot matrix LCD screen

j) Power Supply: Instrument from an external 12V DC adapter power supply voltage (SELV); 

a)  Outside measurement 310 x 190 x 180 (mm)

l) Quality4.8kg

4 Technical requirements 

aTesting range0—140 mm/hresults of  Wechsler);

bTesting relevanceWechsler results of the linear correlation coefficient   r≥0.98

cTesting repetitive : CV < 3% 

5 Main function 

aSample Adding Method  Insert the sample any time; detect the sample any time;

bThe output of the resultsDisplay and print samples’ No. (serial number), Wechsler results and the whole process of erythrocyte sedimentation rate curve, detection time and temperature; when the instrument detection time is 60 minutes, it can automatically calculate, display and print Katz index;

cInstrument can choose the ambient temperature compensation. When selecting the function, when the room temperature is 18  -30 , it amends to 18  according to the blood sedimentation calibration test results. (It can be selected in accordance with laboratory, the default of equipment is no compensated); 

dEquipment can be stored not less than 150 samples of the test results, including the sample number (serial number), erythrocyte sedimentation rate values and the dynamic curve; 

eThere are power-off protection function, when a sudden power failure, automatic detection has been completed the tested  results.

fBuilt-in thermal printer preparation equipment, it has automatic, manual printing options.

gOperation interface: Film keyboard operation; 

hCommunication Interface: RS-232 serial interface; 


Pictures


Service

Packing & Delivery
UPS/DHL/FEDEX/TNT
We ship goods by UPS/DHL/FEDEX/TNT express takes 3~ 5 days to arrive.
By Sea
The volume of goods is large and needs to go by sea.It takes about one month to arrive.

Aircraft
Aircraft transportation takes 2-7 days to arrive.


Q&A

FAQ

Q:What's the minimum order quantity (MOQ)?
A:For most of our medical products, even order for only one unit is warmly welcomed.

Q: Can you do OEM/ private label?
A: Of course we can do OEM/private label for you.


Q: What's your delivery time?
A: Generally it is 10 days if the goods are in stock.
or it is 15-20 days if the goods are not in stock, it is according to quantity.

Q: How to ship the order?
A: Please inform us your instruction, by sea, by air or by express, any way is ok for us. We have very professional forwarder to provide the best shipping cost, service and guarantee.

Q: What is your terms of payment ?
A: We accept T/T ,LC,Western Union ,Paypal and more.Please suggest your preferred payment method.