Defibrillator

Return

Defibrillator

Home  > Products  > Operation Room Equipment > Defibrillator

Products

CUSTOMER CASE

LTHD -8000D Biphasic  Defibrillator
  • LTHD -8000D Biphasic  Defibrillator
  • LTHD -8000D Biphasic  Defibrillator

  • No: LTHD -8000D
  • Type: Defibrillator
  • Dimension:
  • Characteristics:

    Main unit: Portable


  • Details
  • Pictures
  • Service
  • Q&A
  • Physical characteristics:

    Main unit: Portable

    Technical specifications   

    DEFIBRILLATOR.

     (1)Defibrillator type                     Manual, Synchronized, Asynchronized,    

     (2)Out put waveform                   Biphasic technology                                                                            

     (3)Energy accuracy                  ∠+1%

     (4)Energy selection        03571020,3050,100,200,300,360 joule(nominal at a resistance of 50)

     (5)Charging time                      Maximum 8 seconds to 360 Joules

     (6)Standard Adult/Pediatric Paddles   Reusable external adult paddles(pediatric paddles integrated)            

    Power requirements.

    (a)AC Power supply                     110V, 60 Hz /220V,50 Hz  

    (b)Vehicle Voltage             DC 12V

    Internal Battery Backup

    (1)Battery type                 Rechargeable lead-acid battery

    (2)Charging time                 Time-Minimum of 4 hours for full charging    

    (3)Battery charging        During AC Power Supply operation of the device.

    (4)Charging /Low Battery Indication      Red LED                

    (5)Battery Capacity        100% of the battery will provide 120 mins of monitoring; and 30 discharges at 360 joules.

    Display

    -LED Dimensions    7’diagonal {155mm*88mm} which is easily read from a distance.

    -Type                     High resolution true-color graphic LED

    -Resolution            480X234

    - Provide cardioversion facilities with waveform annotated on the screen

    - Display 4 seconds of ECG at 25mm/sec, ECG selectable from leads I, II, III when used with a 3-lead cable, and I, II, III aVL, aVR, aVF and V when used with a 5-lead cable.

    - Display prompts, waveform settings, battery status, event summary and fault codes. Energy selected is displayed by push button under the screen.

    ECG

    ECG lead: Ⅰ, Ⅱ, Ⅲ, AVR, AVL, AVF, V1V6, GND 
    S-T segment analysis: -2.02.0mv 
    Arrhythmia analysis: yes 
    Protection: With stand 4000vAc/50Hz voltage in isolation and work against electrosurgical knife and defibrillation

    Respiration

    Measurement method: Thoracic impedance

    Standard parameter & configuration

     ECG/ RESP/DEFIBRILLATOR

    -Provide audible and visual alarms for heart rate violations, VF and VT. 
    -Provide a strip printer which annotates waveforms, events, time code
    -Have a 5-lead patient cable as an option to a 3-lead cable. 
    -Supplied with external re-usable paddles and packs of paper rolls for the printer.