Patient monitor

Return

Patient monitor

Home  > Products  > Operation Room Equipment > Patient monitor

Products

CUSTOMER CASE

LTSP13 8InchesPatient Monitor
  • LTSP13 8InchesPatient Monitor
  • LTSP13 8InchesPatient Monitor

  • No: LTSP13
  • Type: Patient monitor
  • Dimension:
  • Characteristics:

    Waterproof design, resistance to dropping (1 meter) 


  • Details
  • Pictures
  • Service
  • Q&A
  •  8" color TFT LCD screen, resolution 800*600

    Waterproof design, resistance to dropping (1 meter)

    Low power consumption, fanless structure which

         creates no noise

    Support external 13-20V DC power, continuously working

         for 5.5 hours above on battery backup, full charge with 2.5

         hours, suitable for Ambulance, Emergency Transport

    Display mode: Big font, trends review, 7 leads ECG waveform

          on same screen, and etc

    15 kinds of arrhythmia analysis, 15 kinds of drug concentration

          analysis

    Anti-electrosurgical unit (300W), anti-defibrillation (360J),

          suitable for Operating Room, General Ward

    Digital SpO2 technology, excellent anti- interference

          performance, low perfusion (0.1%)

     

    ECG

    Lead: Standard 3/5 lead

    Lead Mode: 5 Leads (RA, LA, LL, RL,V)

    Lead Selection: I, II, III, avR, avL, avF, V

    Lead Mode: 3 Leads (RA, LA, LL)

    Lead Selection: I, II, III,

    Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV

    HR and Alarm Range:

            Adult: 15 ~ 300 bpm

            Ped/Neo: 15 ~ 350 bpm

    Accuracy: ±1% or±1bpm, which is greater

    Resolution: 1 bpm

    Sensitivity: > 200 (uVp-p)

    Differential Input Impedance: > 5 MΩ

    Bandwidth:

            Surgery    1 ~ 20 Hz

            Monitor     0.5 ~ 40 Hz

            Diagnostic  0.05 ~ 130 Hz

    CMRR:

            Monitor > 100 dB

            Operation > 100 dB

            Diagnosis > 90 dB

    Electrode Offset Potential: ±300mV

    Range: ±2 mV ~ ±700 mV

    Width: 0.1 ms ~ 2 ms

    Rise time: 10 us ~ 100 us

    ST Segment Monitoring Range:

            Measurement Range: -2.0 ~ +2.0 mV

            Measurement Accuracy: -0.8 ~ +0.8 mV

            Measurement Error: ±0.02 mV or ±10%

     

    RESP

    Method: Impedance Between RA-LL or RA-LA

    Measuring Impedance Range: 0.3~3 Ω

    Base line Impedance Range: 200~4 KΩ

    Bandwidth: 0.1~2.5Hz

    Resp. Rate:

            Measuring and Alarm Range:

                Adult: 2 ~ 120 BrPM

                Neo/Ped: 2 ~ 150 BrPM

                Resolution: 1 BrPM

                Accuracy: ±2 BrPM

                Apnea Alarm: 10 ~ 40

     

    NIBP

    Method: Oscillometric

    Mode: Manual, Auto, STAT                        

    Measuring Interval in Auto Mode:

            1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)

    Measuring Period in STAT Mode: 5 Min

    Pulse Rate Range: 40 ~ 240 bpm

    Measuring and Alarm Range:

            Adult Mode

                SYS 40 ~ 270 mmHg

                DIA 10 ~ 215 mmHg

                MEAN 20 ~ 235 mmHg                       

            Pediatric Mode

                SYS 40 ~ 200 mmHg

                DIA 10 ~ 150 mmHg

                MEAN 20 ~ 165 mmHg

            Neonatal Mode

                SYS 40 ~ 135 mmHg

                DIA 10 ~ 100 mmHg

                MEAN 20 ~ 110 mmHg

    Static Pressure Range: 0 ~ 300 mmHg

    Static Pressure Accuracy: ±3mmHg

    Accuracy: Maximum Average Error ±5mmHg

                      Maximum Standard Deviation ±8mmHg

    Overpressure Protection:

            Adult Mode: 300 mmHg

            Pediatric Mode: 240 mmHg

            Neonatal Mode: 150 mmHg

     

     

    SpO2

    Measuring Range: 0 ~ 100 %

    Resolution: 1 %

    Accuracy: 70% ~ 100%  ±2 %

                      0% ~ 69% unspecified

    Pulse Rate:

            Measuring Range: 20~300 bpm

            Resolution: 1bpm

            Accuracy: ±3bpm

     

     

     

    TEMP

    Applicable Temperature Sensor: YSI, CYF

    Channel: 1

    Measuring Range: 0 ~ 50 ℃

    Resolution: ±0.1 ℃

    Accuracy: ±0.1 ℃ (Do not including sensor error)

     

    Dimension: 210*80*175mm (L*W*H)

     

    Weight: 1.35kg

     

    Standard: 3/5-Lead ECG, RESP, SpO2, NIBP, PR, 1-TEMP

    Optional: Mainstream/Sidestream EtCO2, Touch screen


  • Packing & Delivery
    UPS/DHL/FEDEX/TNT
    We ship goods by UPS/DHL/FEDEX/TNT express takes 3~ 5 days to arrive.
    By Sea
    The volume of goods is large and needs to go by sea.It takes about one month to arrive.

    Aircraft
    Aircraft transportation takes 2-7 days to arrive.


  • FAQ

    Q:What's the minimum order quantity (MOQ)?
    A:For most of our medical products, even order for only one unit is warmly welcomed.

    Q: Can you do OEM/ private label?
    A: Of course we can do OEM/private label for you.


    Q: What's your delivery time?
    A: Generally it is 10 days if the goods are in stock.
    or it is 15-20 days if the goods are not in stock, it is according to quantity.

    Q: How to ship the order?
    A: Please inform us your instruction, by sea, by air or by express, any way is ok for us. We have very professional forwarder to provide the best shipping cost, service and guarantee.

    Q: What is your terms of payment ?
    A: We accept T/T ,LC,Western Union ,Paypal and more.Please suggest your preferred payment method.



INQUIRY