LTSI05 Infusion Pump
  • LTSI05 Infusion Pump
  • LTSI05 Infusion Pump

  • No: LTSI05
  • Type: Syringe and infusion pump
  • Dimension:
  • Characteristics:

    Three working modes: Rate/Time/Volume mode



  • Details
  • Pictures
  • Service
  • Q&A

  • Features:

    1. 4.3” color TFT LCD screen (LED backlight), with resolution 272×480

    2. Three working modes: Rate/Time/Volume mode

    3. Drug library with 210 kinds of medicine

    4. Storage 1500 history records

    5. Heating function, suitable for infusing in winter or there is requirement for the fluid medication temperature

    6. Support multi language display

    7. A variety of visible and audible alarm, make infusion more safe

    Standard:Drug library, History record, Heating function, Drip detector Remote control

     

    Optional:SpO2,NIBP

     

    Why we add NIBP &SpO2 to an infusion pump?

    NIBP & SpO2 are the most frequently used vital sign parameters, we  make them work as one, to help doctors reduce cost and save space  which is already very limited in the hospital room.

     

    Technical Specification:

    Infusion rate range

    Adjustable drop rate range: 1 /min~400 drops/min

                              (step: 1 drop /min)

    Adjustable flow rate range: 1ml/h~1200ml/h

                             (step 0.1ml/h)

    Purge rate: 800ml/h

    KVO rate: 1ml/h (less than 100ml/h)

              2ml/h (100~300ml/h)

              3ml/h (greater than 300ml/h)

    Infusion volume range: 1ml~9999.9ml (step: 0.1 ml)

    Maximum accumulated volume: 9999.9ml (step: 0.1 ml)

    Infusion Time range: 1min~9999min (step: 1 min)

     

    Infusion accuracy: Within ±3% (using calibrated high quality IV set)

                       Mechanical precision: within ±2%

     

    Occlusion alarm threshold:

             High: 800 mmHg ± 200 mmHg (106.7kPa±26.7kPa)

    Medium: 500 mmHg ± 100 mmHg (66.7kPa±13.3kPa)

    Low: 300 mmHg ± 100 mmHg (40.7kPa±13.3kPa)

    Alarm: Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle.

     

    NIBP

    Range

    Average deviation: ≤ ±5mmHg

    Standard deviation:  ≤ 8mmHg

    Adult

             SYS: 40mmHg280mmHg

             MEAN: 20mmHg240mmHg

             DIA: 10mmHg220mmHg

    Pediatric

             SYS: 40mmHg220mmHg

             MEAN: 20mmHg170mmHg

             DIA: 10mmHg160mmHg

    Neonate

             SYS: 40mmHg135mmHg

             MEAN: 20mmHg110mmHg

             DIA: 10mmHg100mmHg

    Static pressure

             Range: 0mmHg300mmHg

             Deviation: 3mmHg

     

    Resolution: 1mmHg

     

    NIBP measurement mode

    Manual

    Cycle (automatic):

    Optional interval: 1min, 2min, 3min,4min, 5min, 10min,

    15min, 30min, 60min, 90min

    Fast: continuous NIBP measurement, interval is 5min

    NIBP alarm

    High pressure alarm: >90mmHg-160mmHg

    Low pressure alarm:<50mmHg-90mmHg

    Accuracy: ±5%

    Overpressure protection

    Adult: 280 mmHg ±10 mmHg

    Pediatric: 237 mmHg ±3 mmHg

    Neonate: 147 mmHg ±3 mmHg

     

    SpO2

    Range: 0%100%

    Resolution: 1%

    Accuracy: 70% to 100%, precision is 2%

              0% to 69%, undefined

     

    SpO2 alarm

    Upper limit: 100%

    Lower limit: 90%

    Alarm value accuracy: 3%

    Alarm time accuracy: 2s

     

    Pulse rate

    Range: 20bpm300bpm

    Resolution: 1bpm

    Accuracy: 3bpm

     

    Pulse rate alarm

    Upper limit: 120bpm

    Lower limit: 50bpm (default)

    Alarm value accuracy: 5%

    Alarm time accuracy: 2s

     

    NIBP Cuff requirement

    Human body contact materials: Waterproof cloth

    Size: 515mm(L)×145mm(W), allowed deviation: ±5%

     

    SpO2 sensor

    Type: Finger clip type

    Wire length: 3000mm, allowed deviation: ±5%

    Human body contact materials: Silicone

    Size: 188 mm(L)×198 mm(W)×228 mm(H)

    Net weight: 2.5kg


  • Packing & Delivery
    UPS/DHL/FEDEX/TNT
    We ship goods by UPS/DHL/FEDEX/TNT express takes 3~ 5 days to arrive.
    By Sea
    The volume of goods is large and needs to go by sea.It takes about one month to arrive.

    Aircraft
    Aircraft transportation takes 2-7 days to arrive.


  • FAQ

    Q:What's the minimum order quantity (MOQ)?
    A:For most of our medical products, even order for only one unit is warmly welcomed.

    Q: Can you do OEM/ private label?
    A: Of course we can do OEM/private label for you.


    Q: What's your delivery time?
    A: Generally it is 10 days if the goods are in stock.
    or it is 15-20 days if the goods are not in stock, it is according to quantity.

    Q: How to ship the order?
    A: Please inform us your instruction, by sea, by air or by express, any way is ok for us. We have very professional forwarder to provide the best shipping cost, service and guarantee.

    Q: What is your terms of payment ?
    A: We accept T/T ,LC,Western Union ,Paypal and more.Please suggest your preferred payment method.